Parameters
Parameter
-c controller ID
-s status
Modes
Normal.
Level
Administrator level.
Usage Guidelines
You can change the status of the watchdog on a specified controller by running the command
chgwatchdog -c controller ID -s status.
Example
Enable the status of the watchdog on controller A.
VIS CLI:root>test>chgwatchdog -c 0 -s 0
Success : Command executed success.
System Response
None.

2.4.10 chgbiosid

Function
To set the ID of the preferred BIOS for the next startup.
Issue 06 (2010-05-10)
Description
Specifies the ID of the
controller that the watchdog
belongs to.
Specifies the status of the
watchdog.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Commands
Value
The value options are 0 and
1. They are described as
follows:
0: indicates controller A.
l
1: indicates controller B.
l
The value options are 0, 1,
and 2. They are described as
follows:
0: indicates the enabled
l
status.
1: indicates the disabled
l
status.
2: indicates the stopped
l
status.