Shafts and Glutches
Clutch Waved-plate Phase Difference Inspection
1. Placethe clutch waved-plate (A) on a surface plate,
and set a dial indicator (B) on the waved-plate.
2. Find the bottom (D) of a phase difference ofthe
waved-plate, zero the dial indicator and make a
reference mark on lhe bottom of the waved-plate.
3. Rotate the waved-plate about 72-degrees apart
from the bottom whjle holding the waved-plate by
its circumference. The dial indicator should be at
the top (E) of a phase difference. Do not rotate the
waved-plate while holding its surface, always
rotate it with holding its circumference.
4. Read the dial indicator. The dial indicator reads the
phase difference (C) of the waved-plate between
bottom and top.
Standard: 0.05 mm {0.002 in.l minimum
5. Rotate the waved-plate about 54-degrees. The dial
indicator should be at the bottom of a phase
difference (F and H), and zero the dial indicator.
6. Measure the phase difference at the other two tops
( G a n d l ) o f t h e w a v e d - p l a t e b y f o l l o w i n g s t e p s 3
t h r u 5 .
7. lf the two values of the three measu rements are
within the standard, the waved-plate is OK, lf the
two values of the three measurements are out of
the standard, replace the waved-plate.
c +
::T
14-232