NEC Super Script 4400 Maintenance Manual page 248

Color laser printer
Table of Contents

Advertisement

Code
Description of Error
Developer Clutch (DCLC)
D3
D4
Developer Clutch (DCLK)
Cause of Error
1. Loose/Broken connection
2. Incorrect
voltage at
DCLC ON-N
3. MCTL PWB Failure
MCTL
12CN
DCL(Y)ON-P
3
1. Loose/Broken connection
2. Incorrect
voltage at
DCLK ON-N
3. MCTL PWB Failure
MCTL
12CN
DCL(Y)ON-P
4
Clearance Method
1. Check connection between
Clutch
(DCLC).
2. Check voltages below:
+24V
a)
Voltage drop (
) between ECN14-3 and
ECN2-8 then, replace the clutch (DCLC)
b) Voltage jump (
) between ECN1-3 and
ECN2-12 then, replace IOD2 PWB
3. Replace MCTL PWB
IOD2
ECN1 ECN14
+24V-1
3
1
DCL(C)ON-P
3
ECN2
+ 24V-1
5
PGND
8
SGND
12
1. Check connection between
Clutch
(DCLK).
2. Check voltages below:
a)
Voltage drop (
+24V
) between ECN13-3 and
ECN2-8 then, replace the clutch (DCLK)
b) Voltage jump (
) between ECN1-4 and
ECN2-12 then, replace IOD2 PWB
3. Replace MCTL PWB
IOD2
ECN1 ECN13
+24V-1
4
1
DCL(K)ON-P
3
ECN2
+24V-1
5
PGND
8
SGND
12
Service Error Codes
ECN14 of IOD2 and
DCLC
ECN13 of IOD2 and
DCLK
239

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super script 4400n

Table of Contents