NEC Super Script 4400 Maintenance Manual page 256

Color laser printer
Table of Contents

Advertisement

Code
Description of Error
Heater Fan(HTFAN)
F4
F5
High Voltage Unit(HVU)
Cause of Error
1. Loose/Broken connection
3. Defective Heater
Fan
4. IOD1 Failure
6. MCTL PWB Failure
MCTL
11CN
PGND
2
HTFANON-P
49
1. Charger Unit Improperly
Installed
2. Corona Wire cut/shorted
3. C
ontract failure of the high
voltage (CHV) output
terminal
4. C
ontract failure or short of
CHV socket
5. High Voltage Unit(HVU)
Failure
6. IOD1 Failure
7. MCTL PWB Failure
MCTL
Clearance Method
1. Check the connections between:
a) DCN10 of IOD1 and the heater fan
b) DCN1 of IOD1 and 11CN of MCTL P.W.B.
3. If voltage between DCN10-4 and 5 is
rising edge then replace
3. If voltage between DCN1-49 and 2 is
rising edge then replace
5.Replace MCTL PWB
IOD1
DCN1 DCN10
HTFANON-P
4
12
PGND
5
49
HTFANERR
6
1. Re-install charger unit.
2.
Replace the charger unit or belt cartridge.
3. Adjust contact to make proper connection
4.
Clean the socket part.
5. Replace High Voltage Unit(HVU)
6. Replace
the IOD1
P.W.B.
7. Replace MCTL PWB
IOD1
HVU
DCN14
BCN1
CHV
+24V-1
1
HV
CHVN-N
7
CHVERR
8
Service Error Codes
connector.
the heater fan.
the
IOD1
P.W.B.
Heater Fan
HTFAN
Charger Unit
247

Advertisement

Table of Contents
loading

This manual is also suitable for:

Super script 4400n

Table of Contents