ERROR CODE
E211
(Indicated if iR8500)
Main cause
The thermistor (TH3) inside the fluorescent lamp heater is faulty. The light
adjustment control PCB is faulty. The reader controller PCB is faulty. The
wiring is faulty (short circuit, open circuit).
Condition
0000 The temperature around the fluorescent lamp does to exceed 10°C
E215
(Indicated if iR8500)
Main cause
The thermistor (TH3) inside the fluorescent lamp heater has a short circuit.
The light adjustment control PCB is faulty. The reader controller PCB is
faulty. The wiring is faulty (short circuit, open circuit).
Condition
0000 The reading of temperature around the fluorescent lamp is 170°C
E218
(Indicated if iR8500)
Main cause
The fluorescent lamp is not mounted properly.
Condition
0000 The absence of the fluorescent lamp is detected when the power is
E219
(Indicated if iR8500)
Main cause
The fluorescent lamp has reached the end of its life (inadequate intensity).
The thermistor (TH3) inside the fluorescent lamp heater is faulty.
Condition
0000 The reading of temperature around the fluorescent lamp is 170°C
E-10
2 mins after the fluorescent lamp heater goes on at power-on. Or,
the temperature around the fluorescent lamp is 0°C or lower after
the power is turned on.
or higher while the fluorescent lamp is OFF.
turned on
or higher while the fluorescent lamp is ON.
COPYRIGHT© 2001 CANON INC.
2000 2000 2000 2000
CANON iR8500/7200 REV.1 AUG. 2001