UNIVERGE SV8100
System Hardware Manual
2.6.3.2

Port Defaults

With the default settings, the ports are assigned as follows:
Station Ports:
Virtual
Station Ports:
Trunk Ports:
In the initial configuration:
All Programmable Function keys are line keys (e.g., key
1 is line 1).
All trunks are loop start DTMF.
2.6.3.3

Setting Up Extension Circuit Types

Run Program 10-03 to set up extension circuit types as
required. The system will automatically detect and assign
most circuit types when the device is connected.
1. Dial 10-03-01.
2. Press TRANSFER to Select the slot, port or channel
(with ESIU Blades) to be programmed.
3. Set the terminal type or option as needed.
If the system has DSS Consoles, Program 30-02 must be
.
used to define DSS extension assignments.
As the system recognizes the extension devices
automatically, when replacing the type of device connected,
the type must be undefined in Program 10-03 prior to
connecting the new device. For example, if a port was
previously used for a telephone and a DSS Console is to be
installed in that same port, the telephone must first be
undefined in Program 10-03 before the console is
connected.
Table 4-4 Default Port Settings
Port 1~99 : 200~298
Port 100~300 : 299~499
Port 301~512 : 500~5211
Port 1~99 : 201~299
Port 100~199 : 3601~3700
Port 200~256 : 3701~3757
1~200
Issue 4.1