Chapter 4
Connecting Cables
4.3

Power Synchronized Unit Connection

2
Connect the controller enclosure to the drive enclosure.
(1)
Connect Controller 0 first.
Connect the DI (OUT) port of Controller 0 (CM#0) in the controller enclosure to the DI (IN) port of
I/O module 0 (IOM#0) in the drive enclosure with the mini SAS HD cable between enclosures.
Drive enclosure
Controller enclosure
(2)
When two controllers are installed, connect Controller 1 next.
Connect the DI (OUT) port of Controller 1 (CM#1) in the controller enclosure to the DI (IN) port of
I/O module 1 (IOM#1) in the drive enclosure with the mini SAS HD cable between enclosures.
Drive enclosure
Controller enclosure
4.3
Power Synchronized Unit Connection
When using a power synchronized unit for power control, connect the power synchronized unit to the ETER-
NUS DX.
Refer to "Configuration Guide (Power Synchronized Unit)" for details about power synchronized units, the pro-
cedure for connecting power synchronized units to the ETERNUS DX, and required settings.
4.4

Power Cord Connection

Connect the power cords to the ETERNUS DX.
FUJITSU Storage ETERNUS DX60 S3 Disk storage system Configuration Guide (Basic)