Chapter 5
Power Control Setup
5.2

Connection Setup for Power Synchronized Unit

1
On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2
In [Category], click [System Settings].
The [System Settings] screen appears.
3
In [Action], click [Setup Power Management].
The [Setup Power Management] screen appears.
4
In the [Setup Power Management] screen, select [Enable] for [Auto Power], [Power Resume], or both.
5
Click the [Set] button.
A confirmation screen appears.
6
Click the [OK] button.
The Auto Power function and/or the Power Resume function setting is applied.
7
Check the setting completion message and click the [Done] button.
The screen display returns to the [System Settings] screen.
5.2
Connection Setup for Power Synchronized Unit
Refer to "Configuration Guide (Power Synchronized Unit)" for the required settings to use power control by
connecting power synchronized units to an ETERNUS DX.
FUJITSU Storage ETERNUS DX500 S3/DX600 S3 Disk storage system Configuration Guide (Basic)
83
Copyright 2014 FUJITSU LIMITED
P3AM-7732-05ENZ0