Removing The Fixing Heat Discharge Fan (With Duplex Unit Type) - Canon iR2030 Series Service Manual

Ir2030/2025/2022/2018 series
Hide thumbs Also See for iR2030 Series:
Table of Contents

Advertisement

Chapter 9
5) Remove the fixing heart discharge fan [1].
9.4.9.2 Removing the Fixing Heat Discharge Fan (With
Duplex Unit Type)
1) Draw out the drum unit.
2) detach the rear cover.
3) Detach the left cover (rear).
4) Disconnect the relay harness [2] from the connector [1].
5) Disconnect the ground cable [3].
- Screw [4], 1 pc.
6) Remove the reusable band [5] from the duplex unit harness at the rear-left
of the main body, and then return the duplex unit harness [6] to the left
door side.
[5]
7) Remove the transfer/registration unit [1].
- Screw [2], 4 pcs.
[1]
[2]
9-10
[1]
F-9-38
[3]
[4]
[6]
[1]
[2]
F-9-39
[2]
F-9-40
8) Remove the duplex unit [1] from the left door.
- Screw [2], 6 pcs.
[2]
0017-8827
[2]
9) Disconnect the connector [1], and then release the harness from the wire
saddle [2].
10) Remove the fixing heart discharge fan [1].
[1]
[2]
[2]
F-9-41
[2]
[1]
F-9-42
[1]
F-9-43