- The timing of transmission to UGW varies according to the device.
- The timing of transmission to UGW cannot be set on the side of the device.

10.1.8 Retransmission at the time of SOAP Transmission Error

In case the SOAP transmission error occurs due to the fault at UGW side at the time of the alert code transmission, store the last 3 data failed to transmit in the
RAMDISK, and retransmit it with the predefined intervals.
In addition, in case the SOAP transmission error occurs at the time of the jam log or service call log transmission, retransmit the data failed to transmit with the
predefined intervals. (When transmitting these 2 types of data, RAMDISK is not used, and the number of retransmission is not restricted.)

10.1.9 e-RDS Setting Screen

(1). Setting Items
The forms and default values of the setting items related to the e-RDS in the service mode are as follow:
Service Mode
Setting Items (Meaning)
E-RDS SWITCH
RGW-ADDRESS
(RDS-Gateway ADDRESS)
RGW-PORT
(RDS-Gateway PORT)
COM-TEST
(Communication Test)
COM-LOG
(Communication Log)
(2). Screen Menu
An example for the transition of the menu related to the e-RDS in the service mode.
#E-RDS
E-RDS SWITCH
#E-RDS SWITCH
001
#E-RDS
COM-TEST
#E-RDS
COM-TEST OK
(3). Communication Error Log Selection Screen
The communication error log is displayed by selecting #E-RDS > COM-LOG in the service mode, and pressing the OK key.
The error log to be displayed is as follow:
Communication error log : transmission error of counter and various logs up to the present, as well as the error occurred date, error code, and error information
at the communication test.
By pressing the arrow key (
(Only the No. in which an error is registered can be selected.)
e-RDS OFF/ON 0: OFF/1: ON
When the setting is ON, transmit the counter information and error information to UGW.
Default value: 0 (OFF)
URL of UGW
Default value: the actual URL of UGW
Number of characters: 129 bytes (Including NULL. 1-byte code only)
Port number of UGW
Default value: 443
Setting range: 1 to 65535
Execution of communication test
Judge whether the connection with UGW is established, and display the result with either 'COM-TEST OK' or
'COM-TEST NG'.
Detail of the communication test result
Display the error log for the communication with UGW.
As the error information, occurred time, error code, and error detail information are displayed.
Max. number of log: 5
Error information: max. 128 characters (Excluding NULL)
arrow key
OK key
1
key,
key), the communication error log from No.1 to No. 5 can be checked.
T-10-2
Description
#E-RDS
RGW-ADDRESS
#RGW-ADDRESS
:A
https://xxxxxxxxxxxxxx
#E-RDS
COM-LOG
No:1 Ecode:870F2052
2006 03/24 11:56
F-10-1
#E-RDS
RGW-PORT
#RGW-PORT
001
443
Chapter 10
0017-6741
0017-6742
10-3