#SSSW
No.
Initial setting
SW34
10000000
SW35 - SW50
#MENU
No.
Initial setting
01: - 04:
05:
0
06:
0
07:
10
08:
0
09:
0
10:
1
11: - 20:
#NUMERIC Param.
No.
Initial setting
001:
002:
10 (10%)
003:
15 (15lines)
004:
12 (12times)
005:
4 (4sec)
006:
4 (4sec)
007: - 009:
010:
5500 (55sec)
011:
3500 (35sec)
012:
013:
1300 (13sec)
014:
015:
120 (1200ms)
016:
4 (4sec)
017:
100 (1000ms)
018:
0 (0ms)
019:
200 (2000ms)
020:
100 (1000ms)
021:
0 (0ms)
022:
200 (2000ms)
023:
4
024:
20 (-20dBm)
025:
60 (60sec)
026:
027:
0
028: - 054:
055:
60 (min)
056:
101
Function
waste toner full display setting
not used
Range of
Function
setting
not used
ON/OFF
NL equalizer setting
0: DIAL
line monitor setting
1: SERVICEMAN [1]
2: SERVICEMAN [2]
3: OFF
0-15
transmission level setting
0: 3429
V.34 baud rate
1: 3200
2: 3000
3: 2800
4: 2743
5: 2400
0: 33.6kbs
V.34 transmission speed
1: 31.2kbs
2: 28.8kbs
3: 26.4kbs
4: 24.0kbs
5: 21.6kbs
6: 19.2kbs
7: 16.8kbs
8: 14.4kbs
9: 12.0kbs
10: 9.6kbs
11: 7.2kbs
12: 4.8kbs
13: 2.4kbs
0: 50Hz
pseudo CI signal frequency setting
1: 25Hz
2: 17Hz
not used
Range of setting
Function
not used
(1 - 99)
RTN signal transmission condition (1) setting
(2 - 9)
RTN signal transmission condition (2) setting
(1 - 99)
RTN signal transmission condition (3) setting
(1 - 60)
NCC pause time (pre-ID code) setting
(1 - 60)
NCC pause time (post-ID code) setting
not used
(0 - 9999)
line connection identification time length
(0 - 9999)
T.30 T1 timer (for reception)
not used
(500 - 3000)
T30 EOL timer
not used
(0 - 999)
hooking detection time setting
(0 - 9)
fax/tel switch-over function: between line acquisition and pseudo RBTtransmission
(0 - 999)
pseudo RBT signal pattern: ON time setting
(0 - 999)
pseudo RBT signal pattern: OFF time (short) setting
(0 - 999)
pseudo RBT signal pattern: OFF time (long) setting
(0 - 999)
pseudo CI signal pattern: ON time setting
(0 - 999)
pseudo CI signal pattern: OFF time (short) setting
(0 - 999)
pseudo CI signal pattern: OFF time (long) setting
(0 - 7)
fax/tel switch-over pseudo RBT transmission level
(0 - 20)
fax/tel switch-over pseudo RBT transmission level
(0 - 999)
pseudo RBT signal pattern: OFF time (long) setting
not used
(0 - 20)
V21 low-speed flag preamble detection time length
not used
(0 - 480)
acquisition period of enviormental log data
(0 - 999)
count type select 1