Chapter 10
*1: CA stands for Certificate Authority, which are the institutions which issue electronic certificate used in e-commerce etc.
(1) Communication Test
- Perform the communication test
(2) Transmit all or a part of the following data based on the schedule information obtained from UGW.
- Counter details data
- Service mode counter
- Parts counter
- Mode counter
- ROM version
- Schedule information
- Application debug log
- Environment log (Device condition log)
(3) In case of detecting jam, or alert/service call error from the device, transmit the following to UGW.
- Transmission of alert code (transmit the counter information simultaneously)
Transmit an alert code in case of a change in the status of the device.
Main alert codes are toner LOW/OUT, jam, and door open.
At error recovery, transmit again the data that indicates the recovery.
- Transmission of jam log (transmit the counter information simultaneously)
- Transmission of service call (Error code) log (transmit the counter information simultaneously)
(4) Change of device schedule information
- Check whether there is a processing to execute.
- Update the schedule information.
- Return the result of the operation.
(5) Filtering reception from UGW
- Alert filtering
Transmission Detail List:
Transmission Detail / Process Detail
Communication test
communicatonTest
Counter details data collection/transmission
postGlobalClickCount
Service mode counter collection/transmission
postSeviceModeCounter
Mode counter collection/transmission
postModeCounter
Parts counter collection/transmission
postPartsCounter
ROM version
postFirmwareInfo
Schedule information transmission
postConfiguration
Debug log
postDebugLog
Alert code
postAlert
Jam log
postJamLog
Service call log
postServiceCallLog
Operation list check
getOperationList
Schedule information update
getConfiguration
Environment log (Device condition log) transmission
postEnvironmentLog
Alert filtering
getAlertCodeNotificationList
10-2
T-10-1
Transmission Timing
Either at the time of execution of the service mode
of the device or upon a request from UGW with
'getOperationList'
Once every 16 hours.
Once every 16 hours.
Once every 16 hours.
Once every 16 hours.
Once every 7 days.
Once every 16 hours.
At the time that the log has been accumulated
5kbyte
At the time of change in the device condition
At the time of jam occurrence
At the time of service call occurrence
Once every 16 hours.
Upon a request from UGW
At the time of communication test
Once every 12 hours.
Upon a request from UGW
Remarks
The detailed counter data for each paper size
such as Total.
The counter data tied to the service mode
number. Mainly used for billing.
The counter data by operation mode.
The counter data indicating the amount of
usage by part.
The log data output by an application for
analyzing a malfunction.
The data when a status change occurs.
Includes the jam code, date of occurrence,
total counter at occurrence, paper feeding slot,
and paper size.
Includes the error code, error subcode, date of
occurrence, total counter at occurrence, paper
feeding slot, and paper size.
The environment information inside the
device such as temperature and humidity.
When requested from UGW with
'getOperationList'