Press numeric keypad key 1 on the FUNCTION TEST menu to select the G3 signal transmission test. This test transmits 4800-bps G3 signals from the telephone
line connection terminal and speaker.
Sensor test (6-3: SENSOR)
This mode is used to verify the status of the unit sensors from the touch panel (LCD) indications. Press numeric keypad key 3 on the FUNCTION TEST menu to
select the sensor test. The touch panel (LCD) indications change as the associated sensors turn on and off.
T-15-33
Item
Explanation
G3 signal transmission test
Transmits 4800-bps G3 signals to a telephone line and
speaker.
Not used
Sensor test
Sensor actuation test
ADF test
ADF operation test
Book test
Host machine operation test
Speaker test
Speaker operation test
Not used
Lamp test
Contact sensor illumination test
Line signal reception test
NCU board signal sensor and frequency counter operation test