Chapter 7
4) Remove the transfer registration unit [1].
- Screw [2], 4 pcs.
[1]
5) Remove the feed guide [1].
- Screw [2], 2 pcs.
6) Remove the multifeeder paper presence/absence sensor [1].
- Claw [2], 2 pcs.
- Connector [3], 1 pc.

7.5.10 Manual Feed Pickup Solenoid

7.5.10.1 Removing the Multifeeder Pickup Solenoid

1) Open the front cover.
2) Turn the developer pressure release lever clockwise, and then open the left
door.
3) Draw out the drum unit.
7-14
[2]
[2]
F-7-33
[1]
[2]
F-7-34
[1]
[3]
[2]
F-7-35
4) Remove the transfer registration unit [1].
- Screw [2], 4 pcs.
5) Remove the feed guide [1].
- Screw [2], 2 pcs.
6) Detach the multifeeder connector cover [1].
- Connector [2], 3 pcs.