Reference:
At procedure (4) when indicating the license option, it indicates ' 001 1'. The last digit '1' shows that the license is active.
After transmitting the license the last digit will change to '2', which means that the license has been transmitted.
If the option is standard equipped, the last digit will indicate '3', which means that the license could not be transmitted.
(8) Contact the dealer and inform the function inactive certificate key, serial number of the transmission origin device, and serial number of new transmiting device,
which is necessary to transmit the license.
Upon given information above, new license key will be issued, which the license could be registered to the new transmitting device.
(9) Register the new license key to the transmitted device and confirm that the function is active.

15.12 eRDS Parameter Settings (E-RDS)

15.12.1 Settings Related to e-RDS

Settings related to e-RDS are described below.
Item
E-RDS SWITCH
RGW-ADDRESS
RGW-PORT
COM-TEST
COM-LOG

15.13 Display of Counter Information (COUNTER)

15.13.1 Counters
This copier is furnished with a maintenance/supplies counter set (DRBL-1), which can be used to gain rough measures of when to replace supplies. The counter
set increments by one on counting each sheet of small-sized paper (up to A4/LTR) and by two on counting each sheet of large-sized paper (larger than A4/LTR).
Maintenance counter list
Item
TOTAL (Total counter)
PICK-UP (Paper pickup counter)
FEEDER (Feeder related counters)
Description
e-RDS OFF/ON setting (0:OFF / 1:ON)When used (ON), the counter information and error information are sent
to UGW.Default: 0 (OFF)
URL of UGWDefault: URL of actual UGWCharacter string length: 129 bytes (including NULL, one-byte codes
only)
Port No. of UGW Default: 443Setting range: 1 to 65535
Execution of communication test An attempt is made to connect to UGW, judges whether connection is
successful, and displays "COM-TEST OK" or "COMTEST NG" as the judgment result.
Details of communication test resultThe log of errors in communication with UGW is displayed. The error
information includes the error occurrence time, error code, and details of the error.Maximum log count: 5Error
information length: Max. 128 characters (excluding NULL)
Counter
Explanation
SERVICE1
Service total counter 1
SERVICE2
Service total counter 2
TTL
Total counter
COPY
Total copy counter
PDL-PRT
PDL print counter
FAX-PRT
Fax print counter
REP-PRT
Report print counter
2-SIDE
Double-sided copy/print counter
SCAN
Scan counter
C1
Cassette 1 jam counter
C2
Cassette 2 jam counter
C3
Cassette 3 jam counter
C4
Cassette 4 jam counter
MF
Manual feed tray pickup total counter
2-SIDE
Double-sided paper pickup total counter
FEED
Feeder pickup total counter
DFOP-CNT
ADF open/close hinge counter
T-15-27
T-15-28
Chapter 15
0017-6179
0017-6180
15-33