Report Output Of Communication Error Log; Sleep Operation; Alarm Filtering, Alert Filtering; Ca Certificate - Canon iR2030 Series Service Manual

Ir2030/2025/2022/2018 series
Hide thumbs Also See for iR2030 Series:
Table of Contents

Advertisement

Chapter 10
Example of Operation
By pressing the OK key, it transits to the Communication Error Log Detail Screen.
Max. number of the communication error log: 5
(4). Communication Error Log Detail Screen
The detail information of the communication error log is displayed.
For the message to be displayed, see the 'Error Message List'.
By pressing the Menu key, it returns to the Communication Error Log Selection Screen.
Detail error information: max. 128 characters (excluding NULL)
For instance, in case of the detail error '*Server response error(0x800f0200): getConfiguration Not Found Agent(AgentID = E250SD01)', it is too long to fit in
a screen; thus, display it with multiple screens as shown below. Switch each screen with the arrow key.
*Server response er
ror(0x800f0200) : g

10.1.10 Report Output of Communication Error Log

The communication error log can be output as report.
Operation:
#REPORT > #REPORT OUTPUT > ERDS COM LOG LIST

10.1.11 Sleep Operation

Even in the sleep mode (power saving), the e-RDS executes the transmission if there is a message to be sent.

10.1.12 Alarm Filtering, Alert Filtering

With the instruction from UGW (getOperationList), change the alarm level for the specified alarm code, and transmit only the specified alert code.

10.1.13 CA Certificate

(1). Overview of functions
CA certificate (CA-KEY) is included in the system software System (Default CA certificate. For UGW).
The CA certificate other than the default is installable with SST.
[Outline of the step]
* See 'Downloading System Software' for details.
1. Move it from SST to CA Certificate Install > Flash File System.
2. Turn the power off/on.
Read the CA Certificate file from Flash file system during initialization, and register CA Certificate through the key management module.
3. Check the information in the service mode #NETWORK > #CERTIFICATE > #CA-CERTIFICATE to see if the same one as the installed CA Certificate
has been registered.
(2). The number of CA Certificates stored in the device
The upper limit of CA Certificates stored in the device : 1
(3). Saving the certificate
When executing Service Mode > #CLEAR > CA-KEY and turning off/on the power, the default CA Certificate is loaded on the Flash memory.
If necessary, install CA Certificate with SST.
(4). Update of the certificate
The registered CA Certificate is renewed when overwriting with SST.
(5). Deleting the certificate
The default CA Certificate is automatically installed when deleting CA Certificate in the service mode and turning off/on the power.
Deleting CA Certificate therefore means installation of the default CA Certificate.
10-4
arrow key
No:1 Ecode:870F2052
2006 03/24 11:56
OK key
It transits to the Communication Error Log Detail Screen.
arrow key
etConfiguration Not
Found Agent(AgentI
No:2 Ecode:87053563
2006 03/24 10:23
F-10-2
arrow key
D = E250SD01
F-10-3
)
0017-6743
0017-6744
0017-6745
0017-6746