5.7.4 Enable ILS on a Channel

1. On the Main screen of the TPC, tap a channel.
2. Tap the Test Patterns button and then tap a test pattern.
3. On the Main screen of the TPC, tap Lens Adjust.
4. Tap Enable Automatic ILS to automatically apply the active channel settings.

5.7.5 Alter the Active ILS Settings

1. On the Main screen of the TPC, tap Lens Adjust.
2. Tap Enable Automatic ILS.
3. Tap the directional arrows to adjust the values displayed in the X, Y, and Zoom fields. These values over-
write the ILS settings.

5.7.6 Maintain Lens Position Regardless of Selected Channel

1. On the Main screen of the TPC, tap Lens Adjust.
2. Clear the Enable Automatic ILS check box.
3. Tap OK.
4. Adjust the focus, Horizontal (X) and Vertical (Y) offset, and zoom by tapping the applicable button.
NOTE: This does not over-write the system settings for the ILS. If
the ILS will position the lens to the saved channel settings.
5. If the
lens returns to this remembered location. Also, this setting is remembered across system resets and
reboots.

5.7.7 Reset the ILS

The ILS must be reset when:
• the lens has been moved
• manual adjustments have been made to horizontal or vertical offset, zoom or focus
• a power outage occurred during a channel change
• ILS settings are drifting within a short period of time
1. On the Main screen of the TPC, tap Lens Adjust.
2. Tap Quick Reset. If Enable Automatic ILS is not selected, the lens returns to the stored settings.

5.7.8 Calibrate the ILS

You must calibrate the ILS must when you install a new lens.
1. On the Main screen of the TPC, tap Lens Adjust.
2. Tap Full Calibration. If Enable Automatic ILS is not selected, the lens returns to the stored settings.
CP4230 User Manual
020-100621-02 Rev. 1 (01-2012)
Downloaded From projector-manual.com Christie Manuals
or
Quick Reset
Lens Calibration
buttons are tapped in the Advanced Setup: Lens Setup window, the
Section 5: Projector Operation
is selected again,
Enabled Automatic ILS
5-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp2230

Table of Contents