6.8

SMPTE Errors Window

To open the SMPTE Errors window you need Operator, Administrator, or Service permissions. Tap Menu >
Diagnostics > SMPTE Errors.
The SMPTE Errors window displays a numerical representation of the signal integrity of the HD-SDI signals
sent to the projector on the BNC signal cables. Click Clear Errors to clear all errors.
Table 6.5 Diagnostics: SMPTE Errors Window
Region
SMPTE Error
Counts
SMPTE Error History
Card Cage Temperature
Refresh
CP4230 User Manual
020-100621-02 Rev. 1 (1-2012)
Downloaded From projector-manual.com Christie Manuals
Figure 6-6 Diagnostics: SMPTE Errors Window
Control
Description
292-A Total
The total count of 292-A errors.
292-A Recent
The recent count of 292-A errors.
292-B Total
The total count of 292-B errors.
292-B Recent
The recent count of 292-B errors.
Clear Errors
Resets SMPTE Error Counts to 0. This is used for testing to see if the
error returns.
A history of SMPTE errors.
The card cage temperature to easily diagnose if this is causing the
SMPTE errors.
Returns a list of SMPTE errors.