Christie CP4230 User Manual page 163

Hide thumbs Also See for CP4230:
Table of Contents

Advertisement

Local Settings (LOC)
et the time format and display options for temperature units.
S
SUBCODE
LANG
TEMP
TIME
EXAMPLES:
(LOC+TIME 1) Set time zone to standard 12 hour
(LOC+TIME?1) Get list of formats
(LOC+TIME?)(LOC+TIME!001) Get time format
Lamp Changed (LPC)
Record current lamp information into the lamp history, then start a new entry. Set lamp information of a new lamp
type ID, serial number, and pre-used hours. When the values are set, use the (LPC 1) command to add the record.
SUBCODE
LPID
NONE
PREV
SERL
EXAMPLES:
(LPC+LPID 2) Set lamp type ID
(LPC+SERL "CDX30-001") Set lamp serial number
(LPC 1) Save information to lamp history. Consecutive lamp changes require a 5 - 10 second time difference as writing to
EEPROM is involved.
Lamp File (LPF)
Set or get the current lamp file for the current or a specific channel. This command can also be used to save the
active lamp data to a new or existing lamp file, and delete a lamp file from the system.
SUBCODE
Cxxx
NONE
SAVE
FDEL
EXAMPLES:
(LPF+C101 "Default") Set lamp file for channel 1 to file "Default"
(LPF?L) List all available lamp files
(LPF 1) Set lamp file for current channel to index 1 in file list
(LPF+SAVE "filename") If the file doesn't exist, it will be created. If the file already exits, it will be overwritten.
(ILF+FDEL "LampSetup1") Delete the "LampSetup1" lamp file from the system.
(ILF+FDEL 3) Delete the lamp file at index 3 in the list.
CP4230 User Manual
020-100621-02 Rev. 1 (01-2012)
Downloaded From projector-manual.com Christie Manuals
DESCRIPTION OF USE
Set the current language of the user interface.
Set the temperature units. 0 - Celsius. 1 - Fahrenheit.
Set Time format. 0 - 24 hour, 1 - 12 hour.
DESCRIPTION OF USE
Set lamp type ID for the new lamp
Save lamp information to lamp history
Set lamp previous lamp hours for the new lamp
Set lamp serial number for the new lamp
DESCRIPTION OF USE
Set or get the current lamp file for a specific channel
Set lamp file for current channel
Save the currently active lamp data to a file. Will overwrite an existing file with the same name.
Delete a lamp file from the system.