Internal Test Pattern (ITP) (Continued)
NONE
STUP
USER
EXAMPLES:
(ITP ?) Get current test pattern, 0 means no test pattern is used.
(ITP 4) or (ITP " ") Use number or string to set test pattern
(ITP+USER 4) or (ITP+USER " ") Use number or string to set test pattern from user's test pattern list.
(ITP+FULL 1) Use full screen size
(ITP+FULL 0) Use active channel screen file
(ITP+NOCR 1) Set non-correction test patterns for measured color you can use
(ITP+STUP "DC2K Framing Green, DC2K Framing Red") Add these two test patterns to the user list
(ITP+STUP 1 3) Add these two test patterns indexed in the ITP list to the user list
Lamp Intensity Calibration (LCA)
This control is used to calibrate (correlate) the intensity feedback mechanism to footlamberts. Note the minimum/
maximum power are used to pick two points on the curve. These points will not stay consistent over the life of the
lamp, but the conversion algorithm will extrapolate the conversion beyond the range of the two end points. Foot-
lamberts for minimum/maximum power are converted to integer by multiplying 100 because serial command pro-
tocol does not support floating point number.
calibration.
SUBCODE
MAXF
MAXS
MINF
MINS
NONE
EXAMPLES:
(LCA+MINF 10) Set 10 footlamberts as measured brightness at minimum lamp power
(LCA+MINF?) Get footlamberts on minimum lamp power
(LCA+MINS 5000) Set 5000 as reading value from the light sensor at minimum lamp power
(LCA+MAXF 17) Set 17 footlamberts as measured brightness as maximum lamp power
(LCA+MAXF?) Get footlamberts at maximum lamp power
(LCA+MAXS 15000) Set 15000 as reading value from the light sensor on maximum lamp power
LUT CLUT Control (LCT)
Set Look up Table (LUT) Color Look Up Table (CLUT) file for the specified channel. The CLUT is used during
color processing in the cinema electronics.
SUBCODE
CP4230 User Manual
020-100621-02 Rev. 1 (01-2012)
Downloaded From projector-manual.com Christie Manuals
Select test pattern from full list of defined test patterns
Add test pattern from full list of defined test patterns to the user list
Select test pattern from user defined test pattern list
NOTE
DESCRIPTION OF USE
Set footlamberts at maximum lamp power, the value should be (footlamberts * 100)
Set sensor value at maximum lamp power
Set footlamberts at minimum lamp power, the value should be (footlamberts * 100)
Set sensor value at minimum lamp power
Not available
DESCRIPTION OF USE
: Changing the lamp or lamp alignment will require re-