Output Check List - Konica Minolta 8050 Service Manual

Hide thumbs Also See for 8050:
Table of Contents

Advertisement

KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
8.5

Output check list

Note:
• Do not output items which cannot be set or
changed in the field and codes which are not
described in the output check list."
Classification Symbol
High voltage,
L1
analog signal
M53, MC14
M53, MC15
M53, MC16
M53, MC17
HV1
Code
Multi code
00
0
Exposure lamp
01
0
Toner bottle motor (low speed), toner
bottle clutch /Y
1
Toner bottle motor (high speed), toner
bottle clutch /Y
2
Toner bottle motor (nonvolatile value),
toner bottle clutch /Y
3
Toner bottle motor (low speed), toner
bottle clutch /M
4
Toner bottle motor (high speed), toner
bottle clutch /M
5
Toner bottle motor (nonvolatile value),
toner bottle clutch /M
6
Toner bottle motor (low speed), toner
bottle clutch /C
7
Toner bottle motor (high speed), toner
bottle clutch /C
8
Toner bottle motor (nonvolatile value),
toner bottle clutch /C
9
Toner bottle motor (low speed), toner
bottle clutch /K
10
Toner bottle motor (high speed), toner
bottle clutch /K
11
Toner bottle motor (nonvolatile value),
toner bottle clutch /K
02
0
High voltage unit /1 (charging /Y)
1
High voltage unit /1 (charging /M)
2
High voltage unit /1 (charging /C)
3
High voltage unit /1 (charging /K)
4
High voltage unit /1 (charging /Y: for
current measurement)
5
High voltage unit /1 (charging /M: for
current measurement)
6
High voltage unit /1 (charging /C: for
current measurement)
7
High voltage unit /1 (charging /K: for
current measurement)
1-127
• Do not output items with "x" in the "Cannot be
set or change in the field" column. These
items are only for the developping/manufuct-
ing process.
Outputs of them may damage the machine.
Name
47 MODE
Cannot be set or
changed in the field
x
x
x
x
x
x
x
x

Advertisement

Table of Contents
loading

This manual is also suitable for:

8150Cf5001Bizhub pro c500

Table of Contents