Konica Minolta 8050 Service Manual page 312

Hide thumbs Also See for 8050:
Table of Contents

Advertisement

ERROR CODE LIST
Classification Abnormality
code
Fan
F32-03
abnor-
mality
F32-04
F32-05
F32-06
F32-07
2
KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
Causes
When the paper exit fan /F, /M,
and /R (M28, M27, and M26)
were ON, abnormality detec-
tion signal of either of them
was continuously detected for
the specified time.
When charging air intake fan
(M48) was ON, M48 abnormal-
ity detection signal was contin-
uously detected for the
specified time.
When the drum cooling fan /1
and /2 (M12, M13) were ON,
abnormality detection signal of
either of them was continu-
ously detected for the specified
time.
When the transfer belt cooling
fan (M11) was ON, M11 abnor-
mality detection signal was
continuously detected for the
specified time.
• In the case of the new type
While the paper exit fans /1, /
2 and /3 (M61, M62 and M63)
are turned ON, an error
detection signal of either
M61, M62 or M63 is detected
for the specified period of
time in succession.
• In the case of the old type
For the M61, M62 or M63 that
is not installed, an abnormal
rotation is detected incor-
rectly.
Resulting
operation
Main body
Printer control board (PRCB)
stops immedi-
Paper exit fan /F (M28)
ately and main
Paper exit fan /M (M27)
relay (RL1) is
Paper exit fan /R (M26)
turned OFF.
Toner supply drive board
(TSDB)
Charging air suction fan (M48)
Printer control board (PRCB)
Drum cooling fan /1 (M12)
Drum cooling fan /2 (M13)
Printer control board (PRCB)
Transfer belt cooling fan (M11)
Printer control board (PRCB)
Paper exit fan /1 (M61)
Paper exit fan /2 (M62)
Paper exit fan /3 (M63)
Note:
• Since the old type is not
5-8
Estimated abnormal parts
installed with the M61, M62
and M63, be sure to check
to see if the 25 DIPSW is set
as shown below:
Old type: DIPSW 21-0-0

Advertisement

Table of Contents
loading

This manual is also suitable for:

8150Cf5001Bizhub pro c500

Table of Contents