Konica Minolta 8050 Service Manual page 183

Hide thumbs Also See for 8050:
Table of Contents

Advertisement

KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
5. Loosen 2 solenoid screws [1], adjust the posi-
tion of the solenoid [2], and then tighten the
screws.
Standard value: A = 6.5 ± 0.5 mm
6. Replace the solenoid bracket [1] and tighten the
solenoid bracket screws [5] at the position
where the paper exit guide [2] is in contact with
the stopper (rubber) [4] on the paper exit guide
stay [3].
Note:
• There should be the gap of 1 mm or more
between the paper exit guide [2] and the paper
exit guide stay [3].
7. Reinstall the above parts following the removal
steps in reverse.
[2]
[1]
[1]
[4]
1-151
OTHER ADJUSTMENTS
8050fs1085
[5]
[3]
[2]
[3]
1mm
[2]
8050fs1086

Advertisement

Table of Contents
loading

This manual is also suitable for:

8150Cf5001Bizhub pro c500

Table of Contents