OTHER ADJUSTMENTS
9.27 LCT pick-up release amount
adjustment
Perform the LCT pick-up release amount adjust-
ment when a no feed jam occurs frequently. The
adjustment is performed by changing the horizontal
position of the paper feed solenoid (SD100).
A. Procedure
1. Lift up the up/down plate [1].
2. Open the top cover [2].
3. Remove the sprint [4] from the paper feed unit
[3].
4. Remove 4 screws [5].
5. Remove the paper feed pick-up cover /B [6]
toward right.
KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
[2]
[5]
1-188
[4]
[3]
[1]
[6]
8050fs1073