Konica Minolta 8050 Service Manual page 180

Hide thumbs Also See for 8050:
Table of Contents

Advertisement

OTHER ADJUSTMENTS
6. Remove the rear cover.
7. Unplug all connectors [2] from the FNS control
board (FNSCB) [1] and remove the wiring har-
ness from the clamp [3].
8. Remove 5 screws [4]. Then, remove the FNSCB
[1] with the bracket [5].
9. Loosen 2 screws [2] for the bypass gate sole-
noid (SD705) [1] and adjust the position of SD
705 [1] based on the mark [5] to make the clear-
ance between the bypass gate [3] and the
bypass conveyance plate [4] to be within the
standard value when SD705 [1] is off.
Standard value: A = 3.2 ± 0.5 mm
10. Reinstall the above parts following the removal
steps in reverse.
KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
[2]
[2]
1-148
[3]
[4]
[1]
8050fs1079
[4]
[3]
[5]
[1]
8050fs1080
[5]