KONICA MINOLTA 8050/CF5001/C500/8150 Field Service Ver.3.0 Dec. 2004
Classification Abnormality
code
Image
E46-25
process-
ing
abnor-
mality
E46-26
E46-31
E46-32
E46-35
Causes
AOC/AGC adjustment abnor-
mality
• Blocking cover and lens cover
of scanner section are out of
place.
• CCD board (CCDB) connec-
tor is disconnected.
• CCDB power cable is discon-
nected.
• CCDB IC protector is broken.
• Quantity of light of exposure
lamp (L1) is excess.
• L1 does not light up.
There is no correction data
which has been reserved by
resolution.
Before completion of MPC,
APC initial sampling was
attempted.
Execution of MPC was
attempted during execution of
APC.
Continuous page imaging
range abnormality.
Image cannot be evolved on
memory due to abnormal
image range on memory.
5-19
Resulting
Estimated abnormal parts
operation
Main body
CCD board (CCDB)
stops immedi-
Exposure lamp (L1)
ately and main
Image processing board (IPB)
relay (RL1) is
Printer control board (PRCB)
turned OFF.
Overall control board (OACB)
Scanner drive board (SCDB)
L1 inverter board (L1INVB)
Abnormality
Image processing board (IPB)
detection pro-
Program of overall control
cess is per-
board (OACB)
formed but no
abnormality
code is indi-
cated on the
operation
board and
main body
continues
operation.
Abnormality
code is indi-
cated only for
data collec-
tion, list out-
put and
KRDS.
Main body
Image processing board (IPB)
stops immedi-
ICP program
ately and main
relay (RL1) is
turned OFF.
ERROR CODE LIST