STEP 6 - Install Lens(es)

The lens seals the projector preventing contaminants from entering the
area of the main front electronics. It is important a projector never be
operated without a lens installed.
For Primary Zoom Lens Installation:
1. Ensure the projector's rear safety strap is in place.
2. Turn the lens clamp to the OPEN position. See Figure 2-7.
3. Orient your high-contrast lens with its notches at the top. Fully
insert the assembly straight into the lens mount opening all the way
back without turning. With the lens installed all the way back, it
will seat properly within the lens mount and the aperture will be
oriented correctly. NOTE: Insert a high-brightness lens in the
same manner, with the UP label in the up position for consistency.
4. Position the lens clamp DOWN to lock the lens assembly in place. See
Figure 2-8.
5. Use of the optional lens safety strap is required if the projector is
mounted in a high location where the lens could drop (if it becomes
loose by vibrating) and cause physical injury. NOTE: Use of this strap
is optional if the projector is table-top mounted, but strongly
recommended.
6. Calibrate the lens. See Section 2.6 Basic Image Alignment for details.
For auxiliary Lens Installation (Optional):
To install a 1.25x Anamorphic lens or a 1.26x Wide Converter Lens
(WCL) producing 2.39:1 scope images for large screens, install the
auxiliary lens mount and lens to the projector using the hardware and
instructions provided in the auxiliary Lens Mount Kit (P/N 108-111101-02, P/N 108-111102-xx).

STEP 7 - Install First Lamp

handled. Always wear approved protective safety clothing whenever lamp door is open or
while handling the lamp.
1. Open lamp door.
Using the security key provided, open the lamp door and inspect the empty lamp cooling compartment.
Caution! Do not place heavy objects on the open lamp door.
2. Position anode yoke assembly according to lamp type.
Check the position of the anode yoke assembly for the lamp type that will be used in the projector. Table
2.1 lists all available lamp types for the CP2000-ZX and the position of the lamp yoke assembly.
Table 2.1 Lamp Types Available for CP2000-ZX
LAMP
2.0 kW
CDXL-20
3.0 kW
CDXL-30
3.0 kW
CDXL-30SD (short arc)
CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)
Qualified technician required! High-pressure lamp may explode if improperly
TYPE
Move the lamp cradle as far forward as possible (position closest to igniter)
Move the lamp cradle to the rear position, which is approximately 1" closer to
the reflector.
Figure 2-7 Open Lens Clamp and
and Anode Yoke Position
ANODE YOKE POSITION
Section 2: Installation & Setup
Insert Lens
Figure 2-8 Lock Lens In Place
2-5