Section 2: Installation & Setup
2.5

Maximizing Light Output

(Using the CDP)
To ensure optimal operation and peak screen brightness, activate LampLOC™ to adjust the lamp position
whenever a new lamp is installed in the projector. Once LampLOC™ adjustment is complete, the lamp will be
well-centered and distanced correctly from the remainder of the illumination system.
Before adjusting LampLOC™, ensure the following criteria are met:
The lamp is installed with the anode yoke in the correct location for the lamp type. Refer to Figure 2-
9.
The correct use of the lamp extension nut with CDXL-30SD lamps is met. NOTE: This nut must be
removed if you're not using a CDXL-30SD lamp.
The lamp must be on and the douser (shutter) is opened during adjustment.
Perform a white test pattern. This is recommended to allow you to view LampLOC™ progress on
screen.
To automatically adjust LampLOC™, do the following:
1. From the CDP, select Lamp > LampLOC > LampLOC Auto.
2. Let a few minutes pass to allow the LampLOC™ mechanism to establish the best lamp position and
optimize the light output. You will see 100% displayed on the screen when the operation is complete.
NOTE: LampLOC™ can also be adjusted manually using the CDP LampLOC Manual option or through
the web user interface Advanced: Lamp menu.
2-14
Figure 2-20 Adjusting LampLOC™ From CDP Menu
CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)