Install Lens(Es); Primary Zoom Lens Installation - Christie CP2000-M Setup Manual

Hide thumbs Also See for CP2000-M:
Table of Contents

Advertisement

Section 3: Installation & Setup
3.6

INSTALL LENS(ES)

The lens seals the projector, preventing contamination of the main front
electronics. It is important that a projector never be operated without a lens
installed.

3.6.1 Primary Zoom Lens Installation

1. Turn the lens clamp to the OPEN position
(Figure 3-5).
2. If present, remove the 2 hex screws from the
lens mount (Figure 3-6).
3. Orient the lens so the lens retaining ring
mounts line up with the lens mount.
4. Fully insert the assembly straight into the
lens mount opening without turning (Figure
3-5). When you hear a clicking sound, it
indicates the lens has made contact with the
magnets. These magnetic guides ensure the
lens is properly seated inside the mount, that
the aperture is orientated correctly and that
the connector for motorized zoom and focus
is properly connected.
5. Position the lens clamp DOWN to lock the lens assembly in place (Figure 3-6). Use of the hex
screws is required if the projector is ceiling mounted.
Constant vibrations can cause the lens to become loose and dislodge from
the projector. Failure to use the hex screws could result in physical injury.
3-6
CAUTION
WARNING
F
3-6 L
L
I
IGURE
OCK
ENS
N
F
3-5 I
IGURE
NSERT
P
LACE
CP2000-M/MR Setup Guide
L
ENS
020-100205-03 Rev. 1 (05/09)