Christie CP2000-ZX Setup Manual page 28

Hide thumbs Also See for CP2000-ZX:
Table of Contents

Advertisement

Section 2: Installation & Setup
3. Adjust horizontal boresight bolt as necessary to direct or "aim" the
lens toward the side of the image which focused too close to the lens.
When both sides appear equally blurry, re-focus on the left side of the
screen.
4. Adjust horizontal offset to re-center the image on the screen.
5. Repeat Step 4 and 5 until both sides of the image are well focused.
6. Adjust the Hold screw to lock adjustments in place. Check boresight
again.
Adjust Top/Bottom Boresight:
7. When the left/right boresight is complete, focus the image
at the top edge of the screen.
8. If the bottom remains blurry while the top edge is focused,
refer back to Step 2 but use a paper at the bottom of the
screen to determine whether the bottom of the image is
focused in front of the screen or behind the screen. If the
bottom is well-focused, skip to Step 11.
9. Adjust the vertical boresight bolt using one Allen key to
hold the bottom hex screw and another to turn the adjustment bolt above it.
Adjust as necessary to direct or "aim" the lens toward the edge of the
image which is focused too close to the lens. When both top and bottom
appear equally blurry, re-focus at the top of the screen.
10. Repeat Steps 8 and 9 until the top and bottom of the screen are both well-
focused.
11. Refocus: Although all sides of the image should now be in focus, the
center of the image will be slightly blurry at this point. Refocus at center of
image. The goal is good focus at center and on all sides.
12. Adjust the Hold screw to lock in place, and check boresight again.
2-18
F
2-26
IGURE
F
2-27
IGURE
F
2-28
IGURE
CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)