5.2.5 LiteLOC™ Does Not Seem to Work
1. Make sure LiteLOC™ is enabled in the Advanced: Lamp menu of the web user interface.
2. Changing the Lamp Power setting in the Advanced: Lamp menu disables LiteLOC™.
3. If the lamp power has increased to its maximum in order to maintain a LiteLOC™ setting, LiteLOC™ is
automatically terminated. If the values shown in the Advanced: Lamp menu indicate that the lamp power
has reached this "over-drive" state, either reduce your LiteLOC™ setting or install a new lamp.
5.3

CDP

5.3.1 Blank Screen, No Menu Displaying

Is CDP contrast set so low that you can't tell the display is ON? Navigate to the Configuration menu and
select CDP Contrast. Use the right arrow key to increase the contrast value until something appears.

5.3.2 Projector is ON, but There is No Light at the CDP

1. Confirm the harness is plugged into the back of the CDP.
2. Touch any key - the backlight for the displays and keys should be present.
5.4

Ethernet

5.4.1 Trouble Establishing Communication with Projector

1. From the CDP, Configuration > Administrator > Mgmt Ethernet submenu, check the DLP IP address
and Mgmt IP address with the Subnet Mask. Ensure these belong to the same network.
2. From the CDP, Configuration > Administrator > Auxiliary Ethernet and Mgmt Ethernet submenus,
check Mgmt IP address and auxiliary Ethernet IP address with the Subnet Mask. Ensure these do not
belong to the same network.
3. Make sure the Ethernet settings are valid for your site. All devices should have the same subnet mask yet
unique IP addresses. Refer to Section 3: Operation in the CP2000-ZX User Manual (020-100006-xx).
NOTES: 1)The DLP IP address rarely requires modification and must be different from the projector's IP
address (Mgmt IP address). The DLP IP address should be modified by an experienced network
administrator. On the rare occasion this address is modified, wait 2 minutes to allow the electronics to
reset. The DLP communication error which appears during this time will clear indicating the electronics
have reset. 2) Although the Gateway IP address is defined only once in the web user interface, it should be
the same for both Ethernet controls when defined via the CDP Mgmt Ethernet and auxiliary Ethernet
menus.