Section 2: Installation & Setup
Installing a Pluggable Type B Connection
There must be easy access to the current protection device or breaker in the building. Follow these guidelines:
Use 10AWG or 8AWG wiring: the distance between the wall circuit breaker and the projector must
not exceed 20 metres using 10AWG cables or 30 metres using 8AWG cables.
The socket-outlet is installed near the equipment and is easily accessible.
The plug can be used as the device disconnect and is near the unit and easily accessible.
Figure 2-13 Nema-L630A 250V Male Power Plug (
1. A small electrical access plate is located in the lower right corner of the projector faceplate. Loosen the two
screws and slide the plate forward to expose the terminal block underneath. See Figure 2-14.
2. Remove the knockout plate (four screws) located in the bottom right corner of the front bezel.
3. Connect the AC power source to the terminal block, beginning with the ground lead first. See Figure 2-15
for wiring details. Tighten screws securely.
4. Once all cables are connected, secure the knockout plate (four screws) and the bottom access panel (two
screws) over the terminal block.
2-8
Actual Length 1.5 Meters
Figure 2-14 Remove the Knockout Plate
Figure 2-15 Steps to Connect AC Power to Terminal Block
116-102104-01)
CP2000-ZX Setup Guide
020-100098-04 Rev. 1 (06-2009)