GP 9.3 TRANSFER VOLTAGE
CHECK
PURPOSE
The purpose of this check is to ensure that the
Transfer Voltage is within specifications.
NOTE: You must have a High Voltage Probe to
perform this procedure
Note:
During normal operation the Transfer
voltage will be one of two voltages (1500 volts
for plain paper, and 2800 for transparencies.
1. Set up the multimeter to read 1500 VDC.
2. (Figure 1):
Connect the High Voltage
Probe to the Transfer terminal (black wire,
left).
3. Enter Normal Diagnostics (Menu [3] +
Enter [7], Power ON).
4. Use Menu [3] to scroll to VOL TEST MAIN
CH.
5. Use Next [6]/Previous [5] to scroll to VOL
TEST TC BIAS.
Caution
Check to ensure that the red meter lead is not
contacting the frame.
6. Press Form Feed [1] to switch on the High
Voltage Power Supply Transfer Current.
7. The voltage should be 1200 to 1600 V.
8. Press Media Server [2] to switch the
Power Supply off.
NOTE: Do not keep the power supply on any
longer than necessary.
GENERAL PROCEDURES
GP 9.3
Connecting The Meter
Figure 1. Checking the Transfer Voltage
2/99
6-52
Left Terminal
K7
DocuPrint C55/C55mp/[NC60]