Deleting Of A Device From The System Configuration; Operation With A Service Keyboard - Teletek electronics ECLIPSE 8 Installation Manual

Alarm control panel
Hide thumbs Also See for ECLIPSE 8:
Table of Contents

Advertisement

5. Press ENTER button of the used for programming keyboard. The keyboard will confirm the end of the
successful enrollment procedure with sound signal.
6. The new enrolled device is in normal operation mode and ready for further programming and configuration.

5.4. Deleting of a device from the system configuration

1. Enter engineer code (7777 by default)
2. Enter the address of the device you want to delete from the system configuration.
3. At the respective address press and hold the button "0" for 2-3 seconds – the LCD shows [Free] for the
address, LED 16/ 32 – LEDs from 1 to 16 are lighting on, LED 8 – button "0" lights on. A continuous sound
signal is heard. Attention: Deleting the unique ID number with button "0" is permanent and you cannot
reject the operation with CANCEL button! To enroll the device again follow the procedure described at
items 5.2 and 5.3.

6. OPERATION WITH A SERVICE KEYBOARD

The service keyboard is a device, which is not a part of the system configuration, but can provide full access to all
engineer programming menus. Every keyboard of Eclipse Series can be used as service, when it is not enrolled at
address in the system configuration.
The service keyboard is not enrolled at a certain address and that is why its removing will not cause a system trouble
for a lost device.
To enter the "Service keyboard" mode press the PRG (
You can connect only one service keyboards to the system configuration at the same time.
The "Service keyboard" mode allows access only to the engineer programming menus and the Manager and User
programming menus are not available. The system arming and disarming is also unavailable.
Every Eclipse Series keyboard can be service keyboard if it is not currently connected and enrolled to the system
configuration.
To enter the "Service keyboard" mode with a new keyboard:
-
Connect the keyboard to the system bus and wait the initial initialization to complete.
-
Single press the PRG button (
-
A confirmation sound signal is heard indicating that the keyboard is ready for operation.
-
When you finish with the engineer programming, exit to the main screen.
-
Power off the keyboard and disconnect it from the system bus.
To enter the "Service keyboard" mode with a present keyboard in the system configuration:
-
Use one of the other keyboards in the system configuration to delete the unique ID number of the one
selected for service keyboard – enter the keyboard ID address 8xx0, where "xx" is the device number from
02 to 32 (01 is always the PCB of the control panel), and delete the ID number with pressing the "0" button
for 2-3 seconds. It is not necessary to confirm with ENTER.
Power off the keyboard for a moment – disconnect it from the system bus for 5-6 seconds.
-
-
Connect the keyboard to the system bus again and wait the initialization to complete.
-
Press the PRG (
-
A confirmation sound signal is heard indicating that the keyboard is ready for operation.
-
When you finish with the engineer programming, exit to the main screen.
-
Power off the keyboard and disconnect it from the system bus.
ATTENTION: If the engineer access is disabled from the manager programming menu the access will be
denied and for the service keyboard!
).