Eclipse 8/ 32 Series - Installation Manual

2.1.2 ECLIPSE 32

ECLIPSE 32 Alarm Control Panel is mounted in a white plastic box with dimensions 335 x 290 x 105mm. There are
additional spaces for mounting of one communication module in the box and one expander module (under the main
PCB). For the back-up battery is provided special place. The box is equipped also with a transformer unit and 220V
connection terminal with protective fuse.
The front cover is fixed with two mounting screws and nuts provided in the spare parts kit.
Place for
mounting of
additional
modules
Transformer unit
15-25V/ 50VA
In ECLIPSE 32 final closing, use the supplied screws and nuts in the spare parts kit to fix the front cover to the
mounted bottom.
- Put the nuts into the nests on the backside of the front cover;
- Take the screws with interrupted thread and screw on them into the openings at the front cover bottom
until the nut and the interrupted part come together.
- Fix the front cover onto the mounted bottom;
- Close the cover;
- Screw on the screw for final closing.
Place for mounting of additional modules
Place for back-up battery
12V/ 7Ah
Figure 3. ECLIPSE 32 box elements
Figure 4. ECLIPSE 32 final closing
8
- General support opening of
the box (situated under the PCB);
- Support openings;
- ECLIPSE 32 control panel;
- Mains power supply terminal
with fuse 0.63A;
- Main cable opening;
- Additional cable openings;
Remove the plastic caps from the
box bottom and fix the cable with
them;
- Mains power supply opening;
- Place for mounting of tamper-
switch (the tamper-switch is not
included in the supplied
equipment).
Tamper
regulation

Hide quick links: