2.5. Connection of PGM Outputs

ECLIPSE Control Panels Series – PGM capability:
Control panel
ECLIPSE 8
ECLIPSE 32
The ECLIPSE 8/ 32 Alarm panel PGM1, PGM2, PGM3 and PGM4 outputs have a programmable active level. This
allows them to be used to transmit control signals towards external devices (e.g. a block siren input) or to directly
control low-powered external devices (e.g. relays, LED, etc.).
The internal structure of all PGMs is the same and is shown on Figure 17 a).
Figure 17 b) shows the connection of the relay and a light-emitting diode to the PGM. The active level of this
connection is low.
PGMx Terminal
Permissible current:
- from +12 V - up to 10 mA
- to GND - up to 100 mA
For SIREN output the
current supplied to GND
is up to 1 A.
a)
Figure 17. Internal structure of PGM output and example for connection of LED
PGM 4 has a special functionality and can be programmed for different operation in ECLIPSE 8/ 32 control panels.
In ECLIPSE 8, when set at address 3000, PGM 4 can be used for serial connection to TP2000 transmitter. The serial
link is realized with connection between the AC terminal of the transmitter and PGM 4 on the ECLIPSE 8 – Figure 18.
In ECLIPSE 32, when set at address 3000, PGM 4 can be used for fire zone operating with standard 24V fire base –
see Figure 10 D.
Figure 18. Serial connection between TP2000 transmitter and ECLIPSE 8 control panel
Max. PGM outputs
5
1 (PGM 5), non-monitored
32
Power output, up to 1A
1 (PGM 5), monitored
21
Eclipse 8/ 32 Series - Installation Manual
PGM 4 Functionality
Serial link to TP2000 transmitter
Fire zone for 24V standard fire base
b)