Eclipse 8/ 32 Series - Installation Manual

2.9. Connecting Communication Modules

ECLIPSE 8/ 32 Control panels operate with the whole range universal communication modules produced by Teletek
Electronics. The AJAX family modules support serial interface connection with the ECLIPSE 8/ 32 panels and offer
remote management and programming via the web application AJAX SP Professional.
The supported communication modules are:
- AJAX GPRS. Use a serial interface cable to connect the Eclipse 8/ 32 panel to the GPRS module.
- AJAX LAN. Use a serial interface cable to connect the Eclipse 8/ 32 panel to the GPRS module.
- ARGUS GSM. Connect the +PWR and –PWR terminals of ARGUS module to +AUX and –AUX terminal of the
Eclipse 8/ 32 control panel. Connect the PSTN main line to the LINE connector of ARGUS module. Connect the
PHONE connector of ARGUS module to the RING and TIP terminals of Eclipse 8/ 32. Connect a telephone to RING1
and TIP1 terminals.

3. INITIAL POWER-UP and RESET ALGORITHMS

ATTENTION: The initial power-up of the control panel CANNOT be done with back-up battery supply only!
First, you have to power the panel from the mains and then to connect the back-up battery!

3.1. Initial Power-up algorithm

1. Set a jumper at RESET terminals (see Figures 5 and 6).
2. Switch on the mains power supply.
3. The backlights of all connected to the system bus keyboards will light on permanently. Wait the system initialization.
The system is in ENROLLING MODE and waits for enrolling the first keyboard:
- LCD keyboards. At the screen is displayed the current software revision and text message "Press Enter". The LED
"Lightning" (AC power supply) lights on permanently. Press ENTER button for quick enrolling the device.
- LED keyboards*. The LED "Lightning" (AC power supply) lights on permanently. Press ENTER button for quick
enrolling the device.
4. Connect the BATT leads from the control panel to the terminals of back-up battery as observe the polarity – red wire
to the "+" terminal and black wire to the "-".
5. Enroll the other devices connected to the system bus - the keyboards with single pressing the ENTER button, the
expander modules with pressing the little button between two row terminals, the card reader with placing a card in front
of .
6. Remove the jumper from RESET terminals at the control panel. Do not forget that you can add other devices later
following the Enrolling algorithm described in item 5.
7. Wait until the initialization of the system is running out: the BUS LED blinks for 2-3 seconds in green and then stops.
8. Test the connected detectors and other devices to zone inputs for proper operation.
9. Group the used zones and PGM outputs and program all necessary system parameters.
* Note: When using LED8 keyboard there is no indication on the display, and all digit buttons are lighting on during the
initial power up and after full hardware reset of the system.

3.2. Reset Algorithm

The full hardware reset can be done when the main and back-up power supply is off. Set a jumper at RESET terminals.
Proceed as describe in the item 3.1 - Initial power-up algorithm.