2. INSTALLATION

2.1. Control Panels Mounting

The ECLIPSE series alarm control panels are available in plastic box for wall mounting. There is additional space for
mounting of communication and expander modules in the box.

2.1.1 ECLIPSE 8

ECLIPSE 8 Alarm Control Panel is mounted in a white plastic box with dimensions 290 x 240 x 80mm. There is
additional space for mounting of one communication module in the box. For the back-up battery is provided special
place. The box is equipped also with a transformer unit and 220V connection terminal with protective fuse.
The front cover is fixed with two mounting screws provided in the spare parts kit. Before the installation, break out the
protective caps for the front panel from the bottom box – see the picture below. After fixing the front panel with the
screws put also the protective caps on their places.
Place for mounting of
additional modules
Place for mounting a back-up
batter 12V/ 7Ah
Figure 1. ECLIPSE 8 box elements
Figure 2. ECLIPSE 8 final closing
7
Eclipse 8/ 32 Series - Installation Manual
- General support opening of the
box (situated under the PCB);
- Support openings;
- ECLIPSE 8 control panel;
- Mains power supply terminal with
fuse 0.63A;
- Main cable opening;
- Plastic cap for fixing the mains
power cable;
- Plastic caps for front panel;
- Place for mounting of tamper-
switch (the tamper-switch is not
included in the supplied equipment).
In ECLIPSE 8 final closing, use the supplied
screws in the spare parts kit to fix the front cover
to the mounted bottom.
Use the plastic caps (position
previously broken out from the box bottom to hide
the screw heads at final closing.
at Figure 1)