Eclipse 32 - Teletek electronics ECLIPSE 8 Installation Manual

Alarm control panel
Hide thumbs Also See for ECLIPSE 8:
Table of Contents

Advertisement

Eclipse 8/ 32 Series - Installation Manual

2.2.2 ECLIPSE 32

ECLIPSE 32 - Terminals and components:
17VAC – Power supply from a mains transformer 15-25V / 50VA, fuse 0.63А
GND – Common ground
+/- AUX – Power supply for detectors with consumption up to 0.75А
+PGM – Power supply of auxiliary devices with consumption up to 0.75А
PGM 1-3 – Programmable outputs, 100mA, ОС type (open collector)
PGM 4 – Programmable output / Fire zone (programmed at Menu 3. Programmable outputs), 100mA, ОС type (open
collector)
PGM 5/BELL – Programmable output, high power up to 1А, ОС type (open collector), for connecting siren
Z1-Z8 – Zone inputs
COM – Common ground
RED, GRN, YEL, BLK - System bus interface for connection of keyboards, proximity card readers, expanders, etc.
Jumper RESET – Jumper for total hardware reset of the control panel
Interface Connector – Interface for PC connection
VOICE - Interface connector for mounting of Voice module ECLIPSE VD
BATT – Terminals for connecting the back-up battery
BATT 1 - Battery CR-2032 3V, 120-150mAh (factory mounted on the back of the control panel)
PSTN terminals:
TIP1, RING1 – Connect the telephone
TIP, RING – Connect the PSTN line
GND – Common ground
Fuses, PTC type:
F1 – Fuse for the back-up battery: 2.5A
F2 – Fuse for PGM outputs: 0.75A
F3 – Fuse for AUX outputs: 0.75A
F4 – Fuse for the system bus: 0.5А
LED indication:
PSTN – LED for the status of the built-in digital communicator.
BUS LED – LED for the status of the system bus:
BUS LED
Lights on permanently
Red
RESET Jumper is set
Yellow
Short circuit of the system bus
Green
Selected device of the system bus
Figure 6. ECLIPSE 32 control panel
Wrong connection of the system bus
Normal operation mode
10
Blinks in pulses
Low power supply

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eclipse 32Eclipse 16

Table of Contents