Technical Specifications:
Feature
Power Supply
Consumption
Operation temperature
Tamper
Dimensions, mm
Sound signalization from keyboards
All Eclipse Series Keyboards have sound signalization for occurring of different system events. The sound signalization
has 4 volume levels adjustable at address 90 from the Manager programming menus.
Sound Signal
Description
Button
Single short beep indicating the pressing of a key.
Confirmation
Two long sound signals, indicating the system confirmation to executed operation.
Cancel operation
A single long beep, indicating system incorrectly executed operation.
Entry time
Continuous beep, indicating intrusion into an entrance zone.
Short beeps, indicating the system is armed and the user is required to leave the entrance zone.
Exit time
Ten seconds before the exit time is over beep frequency increases.
Technical
Two short beeps at every 20 sec, indicating a technical trouble. To stop the signalization - press
problem
the TROUBLE button.
Short beeps with subsequently increasing period, indicating intrusion into a zone with an
Chime
activated chime option.
Three sound signals in sequence repeated every 5 seconds. That kind of signalization shows
Fire alarm
activated fire detector in the premises.
Buttons Functions
NOTE: The functionality of BYPASS, TROUBLE and MEMORY buttons for LED8 and LED16 keyboards is accessible
through the manager and user menus only with the respective LED indication on the display.
Button
Function
ENTER
CANCEL
FULL ARM
(or
)
DISARM
(or
)
STAY ARM
SLEEP
ARM
PRG
LED 8
LED 16
Min. 50mA /
Min. 50mA /
Max. 80
Max. 80
100x90x24
Description
Confirmation of the entered data; step ahead in the engineer programming menus.
For LED8 and LED16 keyboards: Use the button to review the memory log file, the system
troubles and the bypassed zones – the respective system LED is blinking during the
review.
Canceling the entered parameters; exit from a programming mode.
Quick button for Full Arming Mode.
The button
is used in the previous design of the keyboard and has the same functionality.
Disarming the system. The button has a special function in text entering mode – deletes
the current symbol and moves the cursor on one position to the left (like Backspace button
on a standard PC keyboard).
The button
is used in the previous design of the keyboard and has the same functionality.
Quick button for Stay Arming Mode. The button has a special function in text entering
mode – shifting between small and capital letters.
Quick button for Sleep Arming Mode.
Entry in Manager and User programming modes. The button has a special function in
engineer programming mode – saving the entered settings and moves forward as the
current index number is increased with +1.
Entry in Service Keyboard Mode.
LED 32
LCD 32
9-18V (nom. 14V)
Min. 60mA /
Min. 60mA /
Max. 140
Max. 100
-20 ÷ +50°C
Yes
110x134x22
17
Eclipse 8/ 32 Series - Installation Manual
LCD 32 Sens.
Min. 50mA /
Max. 100
105x130x22