2.4.4 Supported Proximity Card Readers

Summary for ECLIPSE Series Proximity Card Readers:
Reader
PR IT
The proximity card readers are control devices for management of ECLIPSE 8/ 32 security systems. The ECLIPSE
proximity readers are connected to the system bus observing the polarity.
The readers are equipped with three-color LED indication for the selected arming mode and sound signalization for
announcing current events. The arming and disarming of the system via proximity reader is with using standard
proximity cards, tags or other 125Hz passive transponders.
It is possible that only proximity-card readers be included in a system without having an installed keyboard. In such
systems this would hinder current programming of parameters and cards, as well as Log Review and Technical
Trouble indications. Portable LED or LCD type keyboards can be used to accomplish such tasks.
Up to 8/64 cards can be assigned to one ECLIPSE 8/ 32 security systems - one card for each of the 8/ 64 users.
The Managers in the system are allowed to program the performance of the cards.
Arming and/or disarming rights must be assigned for the respective user code.
The user may not be designated a code combination. In such case the only means to control the security system would
be the proximity-card.
The parameters and functions of the proximity card readers are programmed in Menu 9. DEVICES, according to the
realized system configuration.
Installation of proximity reader PR IT
The PR IT proximity reader is designed for built-in installation in electrical sockets via specialized DIN box. The kit of
the supplied equipment is included only the reader's PCB. The DIN box can be purchased separately.
Description of PR IT elements (Figure 16а):
а)
b)
Figure 16. Proximity card reader PR IT: а) Elements; b) Dimensions of the DIN box; c) Mounting
Technical Specification:
Power supply
Consumption
Operation temperature
Dimensions, assembled
Description
Reader for built-in installation
RED, GRN, YEL, BLK - System bus interface for connection to control panel;
Status LED – LED indicator for the status of the system bus; The LED is blinking
in green during normal operation mode of the reader;
Red, green and yellow LED – LED indicators for the current active arming mode.
The PR IT proximity reader is mounted in a special DIN box – see Figures 16b and
16c.
9 ÷ 18V DC (Nom. 14V)
Min. 70mA/ Max.100mA
-20°C ÷ 50°C
56х46х19mm
ECLIPSE 8
ECLIPSE 32
Position for mounting the PCB
20
c)