SL1100
LED
ACT
Link activity or data transmission and
reception.
LINK1000
1000Base-T link speed indicator
LINK100
100Base-TX link speed indicator.
LINK10
10Base-TX link speed indicator.
4.3
VRS/Voice Mail Card (PZ-VM21)
4.3.1
General
The PZ-VM21 daughter board provides additional DSP resource with 8/16 ch VRS (Voice Response
system) and Voice Mail Service (a compact flash card (CFVMS) is required) and a Single Channel V.34
(33.6 kbps) modem for remote maintenance functions. The daughter board is installed onto the CPU
card.
4.3.2
Unpacking
Items
PZ-VM21
4.3.3
Installing the PZ-VM21 PCB
Do not remove or install the CPU Card with the power on.
1.
Turn off the system power and disconnect AC cord.
2.
Open and remove the Sub-Cover.
2-58
Table 2-19 VOIPDB LED Indications
Function
Table 2-20 Operation of VOIPDB LED Indications
LED
ACT
Off
Off
On
On
Flash
Table 2-21 PZ-VM21 Packing List
PZ-VM21 PCB
Nylon Spacers
LED Status
On Green
LED lights when link up is completed. LED flash
when data is transmitting or receiving.
On Yellow
Lights up when 1000Base-T link up.
On Red
Lights up when 100Base-TX link up.
On Red
Lights up when 10Base-T link up.
LINK1000
LINK100
Off
Flash
On
Flash
On
Flash
Off
Flash
Blinking one by one
List of Contents
ISSUE 1.0
Operation status
Operation status
LINK10
Flash
Internal Error (Hardware
Error)
Flash
Flash
Flash
State of half duplex
transmission (Not
support)
Please change HUB etc.
to full duplex
transmission.
The firmware is being
updated.
QTY
1
4
Installation