Parameter Backup - MUTOH ValueJet 1604 Service Manual

Mutoh valuejet 1604 service manual
Table of Contents

Advertisement

VJ-1604   Maintenance Manual
Confirm IP Adress of Printer
Set IP Address of PC
Execute Board Manager mode
Confirm Firmware installation
7.3.1

Parameter Backup

The NVRAM (Flash-ROM) installed on the MAIN board assembly stores various parameters for the system
operation.
The available backup parameters are as follows.
Panel setting parameters
Mechanism adjustment parameters
Main board-unique adjustment parameters
The MAIN board-unique adjustment parameters cannot be erased or modified.
If the MAIN board assembly is found to need replacement during maintenance operations, make sure to back
up the parameters. The backup data can be used to restore the original system status, omitting some
adjustment steps.
7.3.2
Jigs and Tools
The following jigs and tools are required for parameter backup.
Windows PC:
• CPU: Pentium 400MHz or higher, Installed memory: 128MB or more
• With one of the following installed: Windows 98 SE / Windows Me / Windows 2000 / Windows XP
Workflow for Firmware installation (Version-up Procedure)
Install Firmware
End
Operation using MUTOH Maintenance
Engineer Assistant
Operation using operation panel
7-9
7 Adjustment
Rev.-05

Advertisement

Table of Contents
loading