4 Parts Replacement
(2) Tube Arrangement B
1. Peal the tape off which fixing Y fitting and pull the tube attached to ink pump out from the Y fitting.
No.
1
2
2. Remove and attach the maintenance assembly.
3. Connect the tube attached to ink pump to Y fitting.
4. Secure the Y fitting and tube T-type joint with tape.
No.
1
2
3
When using tape, note the followings:
• Tape type: acetate type or shipping tape (white)
• Length: 70 mm
• Quantity: 2
Rev.-05
Tube attached to ink pump
Y fitting
Y fitting
Tube attached to ink pump
Tube T-type joint
Part name
Part name
4-132