MUTOH ValueJet 1604 Service Manual page 381

Mutoh valuejet 1604 service manual
Table of Contents

Advertisement

VJ-1604   Maintenance Manual
Table 9-5 Symptoms and Check Items for Mechanical Serious Errors (Continued)
No.
Message
4
E071 error
PF overcurrent
Event/
Check item
symptom
Overload
1. Check error history
condition in PF
from "Test 7:
motor (X-axis)
Record" of self-
during printer
diagnosis function.
operation.
2. Set the number of
endurance running
cycles to 50 or more
from "Life 2: PF
Motor" of self-
diagnosis function,
and check if "X
motor error" occurs.
3. Check "Encoder:
PF" from "Check 2:
Test" -> "Test 5:
Encoder" of self-
diagnosis function.
4. PF motor assembly
may be defective.
5. Main board
assembly may be
defective.
-
Check connection of
following MAIN board
assembly connectors.
PF motor cable
assembly
connector: J20
PF_ENC assembly
connector: J12
If NG, check
connection of
MAIN board
assembly
connector: J12.
Replace PF motor
assembly.
Replace MAIN
board assembly.
9-19
9 Troubleshooting
Action
Reference
"5.5.7
History
Menu" p.5-18
"4.4.7
Replacing
MAIN
Board" p.4-
49
"4.6.2
Replacing PF
Motor
Assembly"
p.4-62
"4.4.7
Replacing
MAIN
Board" p.4-
49
Rev.-05

Advertisement

Table of Contents
loading

Table of Contents