9 Troubleshooting
Table 9-6 Error Messages During File Transmission (Continued)
No.
Message
16
Boot Transfer
failed
Opening seq.
failed
Rev.-05
Event/
Check item
symptom
Opening
•
Check connection
sequence of
between control
boot code
board and MAIN
transfer failed.
board.
•
Check if the green
LED on control
board is lit.
•
Check if the red
LED on control
board is blinking.
•
Reconnect control
board and MAIN
board. Otherwise,
replace the cable
connecting control
board and MAIN
board.
•
If the green LED on
control board is off
after the power is
turned on, replace
the control board.
•
If the red LED is
blinking and there is
no problem at
connection between
control board and
MAIN board, try to
reinstall firmware.
•
If the red LED is
off, perform the
following
procedures.
1. Turn off the power,
then switch the DIP
switches as follows:
1: ON
2: ON
3: ON
4: OFF
2. Start the board
manager mode.
3. Reinstall firmware.
4. Turn off the power,
then switch the DIP
switches as follows:
1: ON
2: OFF
3: ON
4: OFF
5. Turn on the power,
then check if the red
LED is blinking.
9-28
VJ-1604 Maintenance Manual
Action
Reference
"4.4.3
Replacing
HEATER
CONT
Board" p.4-
42
"4.4.7
Replacing
MAIN
Board" p.4-
49
"7.3
Working with
Dedicated
Network
Software"
p.7-7