Sram Check; Dram Check - Muratec MFX-1330 Field Engineering Manual

Hide thumbs Also See for MFX-1330:
Table of Contents

Advertisement

3.12.5 SRAM Check

This mode is used to test the SRAM memory where user programmed parameters such as date, time, TTI,
etc are stored.
Note: when this test is executed, the unit will perform an All RAM Clear.
The All RAM Clear erases all user settings and resets all memory switches, machine parameters and unique
switches to factory defaults.
1. Press MENU, *, 1, 1,
SRAM Check
Hex Code:
2. Enter the HEX code (00 ~ FF) using numeric keypad and one-touch key 01 to 06, then press START. The
HEX code is written to, then read from, memory. After that, the result (OK/NG) will be shown in the display.
Then the machine will return to factory function.
The data are written to, then read from, each address. The results are shown in the display. If the
read/write test is successful the display will show "OK".
SRAM Check
OK
If some portion of the read/write test fails the display will show "NG" with the address and the data name.
SRAM Check
NG
3. Upon completion, the machine returns to the test mode.

3.12.6 DRAM Check

This mode is used to test the DRAM memory, or document memory.
Note: When this test is performed, an All DRAM Clear will be performed by the unit. The All RAM clear
erases all user settings and resets all memory switches, machine parameters and unique switches to
factory defaults.
This is a read/write test that requires a few moments to complete.
Note: Perform a DRAM test whenever a memory upgrade is added to the unit.
1. Press MENU, *, 1, 1,
DRAM Check
Hex Code:
2. Enter the HEX code (00 ~ FF) using numeric keypad and one-touch key [01] to [06], then press STRAT.
3. Depending on the amount of DRAM in the unit, press 0, 1, 2, or 3 on the numeric keypad.
Please refer to the following table:
Note: Usually, press "0".
Press
0
All DRAMs
1
The standard memory on the main control board
2
The first half of the 32MB Optional Memory PCB
3
The second half of the 32MB Optional Memory PCB
four times. Then press ENTER.
700100:0000
five times. Then press ENTER.
Check area
3-104

Advertisement

Table of Contents
loading

This manual is also suitable for:

F-300

Table of Contents