10.4.3.7 Removing High pressure switch and pressure switch for control
1  Remove the service cover following
2  Collect the refrigerant from the check joint according to
3  Disconnect the Faston Terminals of High Pressure Switch and Pressure sensor for PD control.
4  Remove the high pressure switch and the pressure switch for control from the brazed part of discharge piping.
Electrical box
Discharge pipe
Brazing
part
High pressure switch
Pressure sensor
for control
10.4.3.8 Opening electrical box (P-Mounting Plate)
1  Remove the service cover following
2  Remove 5 screws which fix the electrical box and open the P plate turning counter clockwise approximately 90°.
Check that the LED201 (red) on the inverter PCB (PCB2) is OFF when opening P-mounting plate.
D A N G E R
DO NOT touch electrical components while the LED201 (Red) or LED1 (Red) are ON to avoid electrical shock. Wait
until the LEDs turn off.