6. Optional functions
Items
Optional function
JA
Not prepared
Jb
Not prepared
K1
Not prepared
K2
Not prepared
K3
Not prepared
K4
Not prepared
K5
Motion sensor detection level
○: Allow individual setting.
×: Setting is used for all the outdoor units
-: Not used
N O T E
*1: The "02" setting may not be available according to the type of indoor unit.
*2: 00: Standard (7-step operation), 01: Draft Prevention (lower 2 steps cutoff), 02: High ceiling (upper 2 steps cut
off)
*3: In case that the set temperature is changed and kept within the set time at "F4", the temperature is automatica-
lly changed to "F5" and "F6". (In case that the set temperature is out of range at "F5" and "F6", it is applied within
upper and lower limit for the set temperature.)
*4: Applicable to fan, cooling and dry operation modes.
*5: Applicable to heating operation mode.
*6: Operation is stopped by pressing the " " (run/stop) switch for 3 seconds.
*7: The sensor value at "C8" will be indicated. When the thermistor for remote control switch is used, the average
value of the thermistor for remote control switch and the thermistor for indoor inlet will be indicated.
*8: When the unit is restarted by the remote control switch, the temperature automatically changes to the setting
temperature of "F5" or "F6".
• After at least 3 minutes from the power ON, not change the optional setting.
• When changing "CF" setting (change of louver swing range), restore the power supply or allow the louver to
make one complete swing fully in the auto swing mode to apply the optional setting.
• The optional settings are different according to the indoor and outdoor unit models. Check to ensure that the
unit has the optional setting or not.
• Record the setting conditions for each optional setting in the "Setting" column of the table.
• The above optional functions with "X" mark at the individual setting can change the condition only when "All
Rooms" is set.
166
SMGB0079 rev.0 - 01/2013
Individual
Setting
setting
condition
00
Not available
-
01
(Use as 00 condition)
00
Not available
-
01
(Use as 00 condition)
00
Not available
x
01
(Use as 00 condition)
00
Not available
x
01
(Use as 00 condition)
00
Not available
x
01
(Use as 00 condition)
00
Not available
-
01
(Use as 00 condition)
00
Standard
-
01
High
02
Low