Ras-(8-10)Hn(P/C)E - Hitachi RAS-2-HVNP Service Manual

Utopia ivx premium / ivx standard h(v)n(p/c)(e) series
Table of Contents

Advertisement

5. Control System
5.2.5  RAS-(8-10)HN(P/C)E
PCB1
PCB1 Connector indication
Connector
PCN1
Fuse
PCN5
Crankcase heater of compressor (oil)
PCN7
Solenoid valve
PCN8
High pressure switch protection
PCN9
Compressor contactor
PCN10
Low pressure switch protection
PCN14
Solenoid valve (only RAS-(8-10)HNPE)
PCN100
4-way solenoid valve
PCN406
Power connection between PCB1 and PCB3
THM7
Outdoor air temperature thermistor
THM8
Pipe evaporation temperature thermistor
THM9
Compressor discharge temperature thermistor
CN5A
Micro electronic expansion valve
CN6
Transmission between PCB1 and DIP-IPM
CN8
Transmission from outdoor to indoor unit
CN100
Discharge pressure (Pd)
CN102
Line connection between PCB1 and PCB3
CN404
Line connection between PCB1 and PCB3
CN405
Motor for fan 2
CN406
Motor for fan 1
EF1,2,3
Power protection
EFR1
124
SMGB0079 rev.0 - 01/2013
Name
PCB3
PCB1 Switch indication
Connector
DSW1
Test run
DSW2
Auxiliary function setting
DSW3
Capacity code
DSW4/
Refrigerant cycle number
RSW1
DSW5
Switch
DSW6
Switch
PCB1 LED indication
LED
Colour
LED1
Red
Power source for the PCB
This LED indicates the transmission status
LED2
Green
between the indoor unit and the RCS
This LED indicates the transmission status
LED3
Yellow
between the indoor unit and the outdoor unit
LED4
Red
Power source at 280V for the PCB
PCB3 Connector indication
Connector
PCN201
Fuse
PCN202
Power connection between PCB3 and PCB1
CN201
Line connection between PCB3 and PCB1
CN202
Line connection between PCB3 and PCB1
EFR1
Power protection
Name
Name
Name

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents